Dew Point and Condensation Calculator for Mold Prevention (free calculator)
summary     Free dew point calculator. Enter air temperature and relative humidity to get the dew point, compare humidity with EPA's 30 to 50 percent target, and check whether a cold surface will condense.

sections
- Reading the result
- Ways to fix condensation

faq
Q: What humidity level causes mold?
A: EPA recommends keeping indoor relative humidity below 60 percent, ideally 30 to 50 percent. Mold risk rises when humidity stays high, and especially when cold surfaces reach the dew point and collect condensation.
Q: What is the dew point?
A: The dew point is the temperature at which air becomes saturated and water vapor condenses. Surfaces colder than the dew point collect condensation.
Q: How do you stop condensation on windows?
A: Lower indoor humidity with exhaust fans, dehumidifiers or ventilation, keep window surfaces warmer with better windows or insulation, and keep air moving across the glass by opening blinds and not blocking heat registers.

note        Free general education based on EPA and CDC mold guidance and OSHA worker-safety principles. It is not an EPA or OSHA certification or a state mold license, not medical or legal advice, and it does not issue a certificate. Nothing you enter on this page is saved or sent.

Courses delivered by HAZWOPER OSHA Training, LLC, an IACET Accredited ProviderDelivered by an IACET Accredited Provider

Free Calculator

Dew Point and Condensation Calculator for Mold Prevention

Find the dew point of the air in a room and check whether a window, wall, pipe or duct is cold enough to collect condensation, one of the most common causes of indoor mold.

  • Runs in your browser
  • Nothing is saved
On this page
  1. Calculator
  2. Reading the result
  3. Ways to fix condensation
  4. FAQ

Condensation forms when air touches a surface colder than its dew point. In buildings, that means wet window sills in winter, sweating pipes and ducts in summer, and damp corners on cold exterior walls, all prime spots for mold.

Reading the result

  • Dew point: any surface colder than this temperature will collect water.
  • Room humidity: EPA recommends keeping indoor RH below 60%, ideally 30 to 50%.
  • Surface humidity: the air right at a cold surface is more humid than the room. When it stays around 80% or higher for long periods, mold risk rises even without visible condensation.

Ways to fix condensation

  • Lower humidity: exhaust fans vented outdoors, dehumidifiers, properly sized air conditioning.
  • Raise surface temperatures: insulate pipes, ducts, walls and window frames; improve windows.
  • Increase air flow: move furniture a few inches off exterior walls, keep interior doors open, don't block supply registers.

Learn more in moisture, humidity and condensation.

Sources and official references

Last reviewed: October 25, 2026 · Free general education based on EPA and CDC mold guidance and OSHA worker-safety principles. It is not an EPA or OSHA certification or a state mold license, not medical or legal advice, and it does not issue a certificate. Nothing you enter on this page is saved or sent.

FAQ

Frequently asked questions

EPA recommends keeping indoor relative humidity below 60 percent, ideally 30 to 50 percent. Mold risk rises when humidity stays high, and especially when cold surfaces reach the dew point and collect condensation.

The dew point is the temperature at which air becomes saturated and water vapor condenses. Surfaces colder than the dew point collect condensation.

Lower indoor humidity with exhaust fans, dehumidifiers or ventilation, keep window surfaces warmer with better windows or insulation, and keep air moving across the glass by opening blinds and not blocking heat registers.

Need Documented Mold Training?